Parameter Name |
Number of Occupied 64 Kbit/s Signaling Links |
---|---|
Description |
This parameter specifies the number of occupied 64 kbit/s SS7 signaling links in the BSC. 2 Mbit/s SS7 signaling links are converted to 64 kbit/s signaling links according to the number of timeslots and are included in this parameter. This parameter varies with the addition or deletion of the SS7 signaling links. The 2 Mbit/s signaling link indicates that the transmission rate of the SS7 signaling link ranges from 64 kbit/s to 2 Mbit/s. Bandwidth of the 2 Mbit/s link = 64 kbit/s x number of selected timeslots |
GUI Value Range |
[0,65535] |
Default Value |
0 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter can only be viewed. You can view this parameter on the M2000. |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |