SGSN NRI Length

Parameter Name

SGSN NRI Length

Description

This parameter specifies the length of the NRI in P_TMSI. It determines which SGSN the MS accesses.

For example, value 0 indicates 0 bit, and value 10 indicates 10 bits.

GUI Value Range

[0,10]

Default Value

If MSC Pool Function Enabled is set to Yes, the default value of this parameter is 1. If MSC Pool Function Enabled is set to No, the default value of this parameter is 0.

Unit

Bit

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

If MSC Pool Function Enabled is set to Yes, the default value of this parameter is 1. If MSC Pool Function Enabled is set to No, the default value of this parameter is 0.

Parameter Relationship

None

BSC Feature

SGSN Pool

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.