Parameter Name |
SGSN NRI Length |
---|---|
Description |
This parameter specifies the length of the NRI in P_TMSI. It determines which SGSN the MS accesses. For example, value 0 indicates 0 bit, and value 10 indicates 10 bits. |
GUI Value Range |
[0,10] |
Default Value |
If MSC Pool Function Enabled is set to Yes, the default value of this parameter is 1. If MSC Pool Function Enabled is set to No, the default value of this parameter is 0. |
Unit |
Bit |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
If MSC Pool Function Enabled is set to Yes, the default value of this parameter is 1. If MSC Pool Function Enabled is set to No, the default value of this parameter is 0. |
Parameter Relationship |
None |
BSC Feature |
SGSN Pool |
Parameter Class |
Parameters About Equipment |
Caution |
None |