Pg State Period(ms)

Parameter Name

Pg State Period(ms)

Description

This parameter specifies the measurement period for calculating the arrival rate of paging messages.

In the measurement period, if the number of paging messages reaches the threshold, the paging messages starts to be discarded until the next measurement period (during which the measurement is restarted) begins.

GUI Value Range

[100,600000]

Default Value

1000

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a small value, the control of the arrival rate of paging messages is sensitive.

If this parameter is set a great value, the control is insensitive.

Recommended Value

1000

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None