Parameter Name |
Table Mask of Critical Level Flow Control Between BM and TC |
---|---|
Description |
This parameter specifies the control table mask of the critical flow control between the TC subrack and the BM subrack. The value of this parameter has 32 bits. Bit9-Bit0 identify the flow control mask of the terminated call, Bit25-Bit16 identify the flow control mask of the originated call. If a bit is set to 1, the message mapping to this bit is discarded, if a bit is set to 0, the message mapping to this bit is not discarded. The BSC determines whether to discard a message based on the message index and the value of this parameter. For example, if the Bit4 of this parameter is 1 when the called message with the index number 5 comes, the BSC discards the message. If the Bit4 of this parameter is 0, the BSC does not discard the message. The index number is 1-10 on the circulation use. |
GUI Value Range |
[0,4294967295] |
Default Value |
28770742 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
28770742 |
Parameter Relationship |
None |
BSC Feature |
Flow Control |
Parameter Class |
Parameters About Equipment |
Caution |
None |