T1(s)

Parameter Name

T1(s)

Description

This parameter specifies the value of T1, that is, the maximum duration from the transmission of the single blocking/unblocking message to the receiving of a response from the MSC.

GUI Value Range

[1,300]

Default Value

30

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

After sending a single blocking/unblocking message, the BSC starts the timer T1. If the BSC fails to receive a response from the MSC before the first expiry of T1, the BSC resends the single blocking/unblocking message to the MSC. If no response is received before the second expiry of T1, the BSC reports the BSC Unable to Block a Circuit or BSC Unable to Unblock a Circuit alarm.

Recommended Value

30

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential