T19(s)

Parameter Name

T19(s)

Description

This parameter specifies the value of T19, that is, the maximum duration from the transmission of the A interface circuit reset message to the receiving of a response from the MSC.

After sending an A interface circuit reset message, the BSC starts the timer T19. If the BSC fails to receive a response from the MSC before the first expiry of T19, the BSC resends the A interface circuit reset message. If no response is received before the second expiry of T19, the BSC reports the BSC Unable to Reset a Circuit alarm.

GUI Value Range

[1,300]

Default Value

30

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

30

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.