Parameter Name |
Flow Control Timer Length Between BM and TC(ms) |
---|---|
Description |
This parameter specifies the value of the timer for the flow control between the TC and BM. When the GSCU in the TC subrack detects that the CPU is overloaded, congestion control in the TC subrack, that is, the flow control between the TC and the BM, is enabled. After this timer expires, the flow control ends. |
GUI Value Range |
[0,5000] |
Default Value |
1000 |
Unit |
Milliseconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a lower value, the GSCU in the TC subrack may still be congested. If this parameter is set to a higher value, the call loss rate may be too high in a long period. |
Recommended Value |
1000 |
Parameter Relationship |
None |
BSC Feature |
Flow control |
Parameter Class |
Parameters About Equipment |
Caution |
None |