Flow Control Timer Length Between BM and TC(ms)

Parameter Name

Flow Control Timer Length Between BM and TC(ms)

Description

This parameter specifies the value of the timer for the flow control between the TC and BM.

When the GSCU in the TC subrack detects that the CPU is overloaded, congestion control in the TC subrack, that is, the flow control between the TC and the BM, is enabled. After this timer expires, the flow control ends.

GUI Value Range

[0,5000]

Default Value

1000

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a lower value, the GSCU in the TC subrack may still be congested.

If this parameter is set to a higher value, the call loss rate may be too high in a long period.

Recommended Value

1000

Parameter Relationship

None

BSC Feature

Flow control

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.