MAX Retrans Reset Circle Message on A-Interface

Parameter Name

MAX Retrans Reset Circle Message on A-Interface

Description

This parameter specifies the maximum number of retransmitted A interface circuit reset messages.

When the circuits on the A interface at the BSC side are reset, the BSC sends a reset message to the MSC and starts a timer.

If the BSC fails to receive a response from the MSC before the timer expires, the BSC resends the A interface circuit reset message.

GUI Value Range

[0,65535]

Default Value

2

Unit

Times

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

2

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.