Parameter Name |
Support NR_of_FDD_cells Writing |
---|---|
Description |
This parameter is used to control the values of FDD_INDIC0, NR_OF_FDD_CELLS, and FDD_Cellinformation in 2QUATER and MI. If there are neighbor 3G cells with the scrambles of 0 and this parameter is set to Yes, then: FDD_INDIC0:1, NR_OF_FDD_CELLS: excluding the cells whose scrambles are 0 FDD_Cellinformation: excluding the cells whose scrambles are 0 If there are neighbor 3G cells with the scrambles of 0 and this parameter is set to No, then: FDD_INDIC0:1, NR_OF_FDD_CELLS: including the cells whose scrambles are 0 FDD_Cellinformation: including the cells whose scrambles are 0 |
GUI Value Range |
[No,Yes] |
Default Value |
Yes |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
Yes |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |