Disconnect Handover Protect Timer(s)

Parameter Name

Disconnect Handover Protect Timer(s)

Description

After receiving a DISCONNECT message from the MS, the BSC does not allow the MS to perform handover during the period set by this parameter. Therefore, the following case can be avoided: After being handed over to the target cell, the MS cannot be put on hook because it does not receive a release acknowledgement message.

GUI Value Range

[0,15]

Default Value

3

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to 15, you can infer that the protection function is not enabled.

Recommended Value

3

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential