Ater Connection Path Index

Parameter Name

Ater Connection Path Index

Description

This parameter specifies the index of the Ater connection path to be bound.

GUI Value Range

[0,255]

Default Value

255

Unit

None

Step

-

Modification Rules

None

Configuration Policy

The Ater Connection Path Index must be set to the index of the configured Ater connection path. Otherwise, the binding of timeslots on the Ater interface does not take effect and this parameter needs to be reconfigured.

If this parameter is set to 255, the timeslots on the Ater interface are not bound.

Recommended Value

255

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.