Parameter Name |
Support PCIC Check |
---|---|
Description |
This parameter specifies whether to enable the PCIC check function on the Pb links between the BSC and the external PCU. When the configuration of the PCIC of the BSC is inconsistent with that of the external PCU, a corresponding alarm is reported to the site maintenance terminal, the Pb interface circuit with inconsistent configurations at two ends are blocked, and the priority of the Pb link is lowered. |
GUI Value Range |
[No,Yes] |
Default Value |
No |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
No |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
This parameter is applicable for only the external PCU mode. |