Parameter Name |
Double-transceiver receive sensitivity |
---|---|
Description |
This parameter is one of the items in the formula for calculating the UL and DL balance performance measurement. The default value of this parameter is 11250, which indicates -112.5 dBm. |
GUI Value Range |
[10000,11500] |
Default Value |
11250 |
Unit |
dBm |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
11250 |
Parameter Relationship |
1. If a TRX is not configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain 2. If a TRX is configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain - Loss and sensitivity The BTS sensitivity described in the preceding formulas varies on the basis of the BTS type. If a double-transceiver BTS is used, the BTS sensitivity equals the double-transceiver receive sensitivity. If a non double-transceiver BTS is used, the BTS sensitivity equals the non double-transceiver receive sensitivity. |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |