Parameter Name |
Loss and sensitivity |
---|---|
Description |
If a TRX is not configured with the TMA, this parameter is one of the items in the formula for calculating the UL and DL balance performance measurement. |
GUI Value Range |
[0,800] |
Default Value |
320 |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
320 |
Parameter Relationship |
1. If a TRX is not configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain 2. If a TRX is configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain - Loss and sensitivity The diversity gain described in the preceding formulas varies with the RF receive mode. If the RF receive mode is set to 4-way receive diversity, the diversity gain equals Four-way diversity gain. If the RF receive mode is set to 2-way receive diversity, the diversity gain equals Two-way diversity gain. |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |