| Parameter Name | Loss and sensitivity | 
|---|---|
| Description | If a TRX is not configured with the TMA, this parameter is one of the items in the formula for calculating the UL and DL balance performance measurement. | 
| GUI Value Range | [0,800] | 
| Default Value | 320 | 
| Unit | dB | 
| Step | - | 
| Modification Rules | None | 
| Configuration Policy | None | 
| Recommended Value | 320 | 
| Parameter Relationship | 1. If a TRX is not configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain 2. If a TRX is configured with a TMA, the formula for calculating the UL and DL balance performance measurement is as follows: UL and DL balance performance measurement = DL receive level - UL receive level - (MS sensitivity - BTS sensitivity) - diversity gain - Loss and sensitivity The diversity gain described in the preceding formulas varies with the RF receive mode. If the RF receive mode is set to 4-way receive diversity, the diversity gain equals Four-way diversity gain. If the RF receive mode is set to 2-way receive diversity, the diversity gain equals Two-way diversity gain. | 
| BSC Feature | None | 
| Parameter Class | Parameters About Equipment | 
| Caution | None |