Parameter Name |
OML Lapd Link Detect Time(s) |
---|---|
Description |
This parameter specifies the detecting time of Abis-Bypass site OML when it is broken. |
GUI Value Range |
[4,255] |
Default Value |
10 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If the parameter value is set relatively small, the sensitivity for detecting the OML when it is broken is improved. When the parameter value is set too small and if the link is intermittently disconnected, misjudgements may occur to the testing results. If the parameter value is set relatively large, the sensitivity for detecting the OML when it is broken is reduced. The testing results are reliable, though. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |