IBCA Information Report Period Between BSC

Parameter Name

IBCA Information Report Period Between BSC

Description

This parameter specifies the period for the completion of information interaction between BSCs. This information is used for the estimation of C/I ratio in the IBCA algorithm.

GUI Value Range

[2,600]

Default Value

8

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

By default, this parameter is set to 2. If the query result shows that the CPU usage of the GXPUI remains high, the parameter should be set to a larger value.

Recommended Value

None

Parameter Relationship

None

BSC Feature

Channel Management

Parameter Class

Parameters About Radio Resources

Caution

The parameter IBCA Allowed should be set to Yes before the configuration of this parameter.


Huawei Proprietary and Confidential