T203(s)

Parameter Name

T203(s)

Description

This parameter specifies the timer of the LAPD protocol. The value of timer specifies the maximum duration of no frame exchange in the LAPD link.

GUI Value Range

[1,10]

Default Value

1

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

For no call drop in ring rotating, two sets of data are recommended. It is suggested that the configuration is based on the recommended data.

When the transmission quality is good, the following data is recommended: ring II waiting time before rotate(s) equals 0; ring II try rotating duration time (s) equal 60; ring II rotating penalty time (s) equals 0; T200 (10 ms) equals 12; T203 (s) equals 1; N200 (times) equals 3.

When the transmission quality is poor, the following data is recommended: ring II waiting time before rotate(s) equals 30; ring II try rotating duration time (s) equal 60; ring II rotating penalty time (s) equals 0; T200 (10 ms) equals 24; T203 (s) equals 3; N200 (times) equals 3.

Recommended Value

1

Parameter Relationship

None

BSC Feature

BTS Ring Topology

Parameter Class

Parameters About Equipment

Caution

This parameter is not applicable to the BTS2X series.


Huawei Proprietary and Confidential