Clock Parameter Allowed

Parameter Name

Clock Parameter Allowed

Description

This parameter specifies whether extended clock parameters are available.A site can be configured with up to nine BTS3006C cabinets at present, each supporting four dry contact alarms, and 36 dry contact alarms in total.In the clock parameters of the BTS extended attributes, a certain bit can be set to shield/unshield a corresponding dry contact alarm.A common BTS requires 24 dry contact alarms at most. The BTS3006C, however, requires expansion. This parameter determines whether the expansion is required.

GUI Value Range

[No,Yes]

Default Value

No

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

None

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

This parameter is configured only for the BTS3006C and BTS3002E.


Huawei Proprietary and Confidential