Locking BCCH Trx When Site Power Off Allowed

Parameter Name

Locking BCCH Trx When Site Power Off Allowed

Description

This parameter specifies that when the site is powered off, the BCCH TRX is locked. When the BSC receives the call drop report from the BTS and this function is disabled, only the TRXs (configured as Shut Down Enable) rather than main BCCH TRXs are disabled; if this function is set to yes, all TRXs under the site including the main BCCH TRXs are disabled so as to fulfill energy efficiency.

GUI Value Range

[No,Yes]

Default Value

No

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

None

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential