Site Synchronization Zone

Parameter Name

Site Synchronization Zone

Description

This parameter specifies the synchronization zone of the BTS. If different BTSs share the same synchronization zone, they are synchronized with each other during the same synchronization task.

GUI Value Range

[0,255]

Default Value

255

Unit

None

Step

-

Modification Rules

None

Configuration Policy

The value of this parameter indicates the number of the synchronization zone. If different BTSs need to be synchronized with each other during the same synchronization task, set this parameter to the same value.

Recommended Value

None

Parameter Relationship

Symbol Offset

BSC Feature

Soft-synchronized network

Parameter Class

Parameters About Radio Resources

Caution

The double-transceiver BTSs of the BTS3012 series and the later BTS types such as the 3900 series base station support the BTS synchronization zone function. The BTS3X series do not support this function.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.