Parameter Name |
Out-BSC Port No. |
---|---|
Description |
This parameter specifies the out-BSC port number on the interface board used by the semi-permanent link. When the semi-permanent link is configured on the electrical interface board, each electrical interface board is configured with 32 E1 ports, which are numbered from 0 to 31. When the semi-permanent link is configured on the optical interface board, each optical interface board is configured with 84 E1 ports, which are numbered from 0 to 83. |
GUI Value Range |
[0,83] |
Default Value |
None |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter cannot be set to the number of the occupied E1 port. If all semi-permanent links are configured on one interface board, the In-BSC Port No. and the Out-BSC Port No. must be set to different E1 ports on the interface board. |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
Semipermanent link |
Parameter Class |
Parameters About Equipment |
Caution |
None |