Out-BSC Port No.

Parameter Name

Out-BSC Port No.

Description

This parameter specifies the number of the out-BSC port where the BSC interface board is located. That is, the number of the port on the interface board, which connects the BTS to the BSC.If the BTS supports the ring network, you can infer that This param

GUI Value Range

[0,83]

Default Value

255

Unit

None

Step

-

Modification Rules

None

Configuration Policy

This parameter is to be viewed only.

Recommended Value

None

Parameter Relationship

None

BSC Feature

Monitoring timeslot

Parameter Class

Parameters About Equipment

Caution

This parameter cannot be set to the number of the occupied E1 port. If all monitoring timeslots are configured on one interface board, the In-BSC Port No. and the Out-BSC Port No. must be set to different E1 ports on the interface board.