Parameter Name |
Penalty on Fast Moving HO |
---|---|
Description |
If an MS is moving fast, the BSC performs penalty on the neighbor cells of the cell where the MS is located. This parameter specifies the penalty value. Only when the MS is located at the Umbrella layer and the neighbor cells are located at the Macro, Micro, or Pico layer, penalty is performed. This parameter is valid within only the Penalty Time on Fast Moving HO. |
GUI Value Range |
[0,63] |
Default Value |
30 |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a small value, the MS is likely to be handed over to a micro cell again, thus leading to ping-pong handovers. If this parameter is set to a great value, the MS is unlikely to be handed over to a micro cell. |
Recommended Value |
30 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |