Parameter Name |
Penalty Time on Fast Moving HO |
---|---|
Description |
This parameter specifies the period in which penalty is performed on the neighbor cells of the cell where a fast-moving MS is located. The neighbor cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer. |
GUI Value Range |
[0,255] |
Default Value |
40 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a small value, the MS is likely to be handed over to a micro cell again, thus leading to ping-pong handovers. If this parameter is set to a great value, the MS is unlikely to be handed over to a micro cell. |
Recommended Value |
40 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |