Parameter Name |
CCCH Load Indication Period(s) |
---|---|
Description |
This parameter specifies the interval for sending the overload messages. This parameter is used by a BTS to inform the BSC of the load on a CCCH timeslot.For details, see GSM Rec. 08.58.If the load on a CCCH timeslot exceeds the CCCH Load Threshold, the BTS periodically sends the CCCH overload message to the BSC. The CCCH overload messages include the uplink RACH overload messages and the downlink PCH overload messages. |
GUI Value Range |
[0,255] |
Default Value |
15 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If the value of this parameter is too small, the signaling is frequently reported, thus bringing more burdens to the BSC. If the value of this parameter is too large, the BSC cannot obtain the information about the RACH load and PCH load in time. |
Recommended Value |
15 |
Parameter Relationship |
None |
BSC Feature |
Channel Management |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |