Frame Start Time

Parameter Name

Frame Start Time

Description

This parameter specifies the start frame number of the BTS. It is used to synchronize the MS and the BTS after the BTS is re-initialized.

The frame offset technology arranges the frame numbers of different cells under the same BTS to be different from one another by one frame offset. Thus, the FCH and SCH signals of adjacent cells do not appear in the same frame to facilitate the MS decoding.

GUI Value Range

[0,65535]

Default Value

65535

Unit

None

Step

-

Modification Rules

None

Configuration Policy

For the BTS2X, BTS3001C, BTS3001C+, and BTS3002C, this parameter is invalid. For other BTSs, this parameter is valid.

Recommended Value

65535

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.