Parameter Name |
CRO(2dB) |
---|---|
Description |
This parameter specifies the manual correction of C2. If this parameter is properly configured, the number of handovers can be reduced and a better cell can be assigned to the MS. When PT is set to 31, it becomes more difficult for an MS to access the cell when CRO increases. Generally, the CRO should be less than 25 dB because excessively large CRO may bring uncertainties to the network.In addition, the same CRO applies to the cells with the same priority.For details, see GSM Rec. 05.08 and 04.08. This parameter affects only GSM Phase II MSs or GSM PhaseII+ MSs. |
GUI Value Range |
[0,63] |
Default Value |
0 |
Unit |
Levels |
Step |
2dB |
Modification Rules |
None |
Configuration Policy |
The settings of RXLEV-ACCESS-MIN and CRO should guarantee that cells with same priority have the same cell reselect offset. |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |