Parameter Name |
ECSC |
---|---|
Description |
The early classmark sending control (ECSC) specifies whether the MSs in a cell use early classmark sending. For details, see GSM Rec. 04.08.After a successful immediate assignment, the MS sends additional classmark information to the network as early as possible. The CM3 (classmark 3) information contains the power information of each band of multi-band MSs. In the inter-band handover, power class must be correctly described. When paging is made or the BA2 table is sent between different bands, the CM3 message must be known. For dual-band MSs, if ECSC is set to No, the MSC sends a CLASSMARK REQUEST message after the MS reports an EST IND message. The MS then reports the CLASSMARK UPDATE message. The connection time of the MS is affected. |
GUI Value Range |
[No,Yes] |
Default Value |
No |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
For a 900/1800 MHz CoBCCH cell, it is recommended that this parameter be set to Yes. For a 1800 MHz cell in the dual-band network, it is recommended that this parameter be set to Yes. If the A5/4-7 encryption algorithm is used, it is recommended that this parameter be set to Yes. |
Recommended Value |
For a 900/1800 MHz CoBCCH cell, it is recommended that this parameter be set to Yes. |
Parameter Relationship |
None |
BSC Feature |
Channel assignment |
Parameter Class |
Parameters About Radio Resources |
Caution |
ECSC is valid only for dual-band MSs. |