Parameter Name |
Scale Order |
---|---|
Description |
This parameter indicates that when the MS reports the EMR, it adds the value of this parameter to the received signal level, and then converts the result into the RXLEV value. For details, see GSM Rec. 05.08. If the SCALE_Order reported by the MS is 10 dBm, level values 0-63 map with -100 dBm to -37 dBm. If the SCALE_Order reported by the MS is 0 dBm, level values 0-63 map with -110 dBm to -47 dBm. If the SCALE_Order reported by the MS is Automatic, the MS chooses the least SCALE while ensuring that the MS can report the most strong level. |
GUI Value Range |
[+0dB,+10dB,Automatic] |
Default Value |
+0dB |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
+0dB |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |