Min Interval for TCH HOs

Parameter Name

Min Interval for TCH HOs

Description

After a new TCH is assigned to an MS, the MS can be handed over to another channel only if the time during which the MS occupies the TCH is longer than the period specified by this parameter.

GUI Value Range

[0,60]

Default Value

2

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

This parameter can be used to avoid unwanted handovers due to inaccurate measurement reports in the initial phase of call establishment.

If measurement reports are processed on the BTS side, you can set Report Frequency of the Preprocessed Measurement Reports smaller than the report frequency of the measurement reports from the MS. Therefore, it is recommended that Min Interval for TCH HOs be set to a small value.

If measurement reports are processed on the BSC side, the frequency of receiving measurement reports on the BSC side is greater than that on the BTS side. Therefore, it is recommended that Min Interval for TCH HOs be set to a great value.

Recommended Value

2

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential