Parameter Name |
Min Interval for SDCCH HOs |
---|---|
Description |
After a new SDCCH is assigned to an MS, the MS can be handed over to another channel only if the time during which the MS occupies the SDCCH is longer than the period specified by this parameter. |
GUI Value Range |
[0,60] |
Default Value |
2 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter is used to avoid unwanted handovers due to inaccurate measurement reports generated in the initial phase of call establishment. If measurement reports are processed on the BTS side, you can set Report Frequency of the Preprocessed Measurement Reports smaller than the report frequency of the measurement reports from the MS. Therefore, it is recommended that Min Interval for SDCCH HOs be set to a small value. If measurement reports are processed on the BSC side, the frequency of receiving measurement reports on the BSC side is greater than that on the BTS side. Therefore, it is recommended that Min Interval for SDCCH HOs be set to a great value. |
Recommended Value |
2 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |