Parameter Name |
Min Interval for Consecutive HOs |
---|---|
Description |
This parameter specifies the minimum interval between two consecutive handovers. No handover is allowed during the minimum interval. A timer starts after a handover is complete, and a subsequent handover is allowed only after the timer expires. The value of this parameter is the length of the timer. The parameter is used to avoid frequent handovers. |
GUI Value Range |
[0,60] |
Default Value |
4 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a too small value, frequent handovers cannot be avoided. If this parameter is set to a too great value, handovers cannot be performed timely. |
Recommended Value |
4 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |