Min Interval for Emerg.HOs

Parameter Name

Min Interval for Emerg.HOs

Description

This parameter specifies the minimum interval between two consecutive emergency handovers. No emergency handover is allowed during the minimum interval.

When the conditions for an emergency handover are met, an emergency handover timer is started. Another emergency handover decision can be made only when the timer expires.

GUI Value Range

[0,60]

Default Value

4

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too small value, frequent handovers cannot be avoided. If this parameter is set to a too great value, handovers cannot be performed timely.

Recommended Value

4

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.