Parameter Name |
Min Interval for Emerg.HOs |
---|---|
Description |
This parameter specifies the minimum interval between two consecutive emergency handovers. No emergency handover is allowed during the minimum interval. When the conditions for an emergency handover are met, an emergency handover timer is started. Another emergency handover decision can be made only when the timer expires. |
GUI Value Range |
[0,60] |
Default Value |
4 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a too small value, frequent handovers cannot be avoided. If this parameter is set to a too great value, handovers cannot be performed timely. |
Recommended Value |
4 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |