Parameter Name |
Penalty Level after HO Fail |
---|---|
Description |
This parameter specifies the penalty level imposed on the target cell. This parameter is valid only within the duration of the cell penalty time. The penalty level values 0 through 63 map to -110 dBm to -47 dBm. |
GUI Value Range |
[0,63] |
Default Value |
30 |
Unit |
Levels |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter specifies the penalty level imposed on a target cell. A penalty level is imposed on a target cell to avoid further attempts when a handover fails due to any of the following reasons: cell congestion, a message indicating internal handover refusal is received, a message indicating Um interface handover failure is received during out-going BSC handover, or a message indicating Um interface handover failure is received during internal handover. This parameter is valid only within the duration of the cell penalty time. |
Recommended Value |
30 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |