Parameter Name |
Penalty Time after BQ HO(s) |
---|---|
Description |
This parameter specifies the duration of the penalty imposed on the original cell where an emergency handover associated with bad signal quality is initiated. During the penalty time, the receive level of the original serving cell is decreased by the penalty level. Thus, other cells are given higher priority and handover to the original serving cell is not allowed. |
GUI Value Range |
[0,255] |
Default Value |
10 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a lower value, the MS is likely to be handed over to the original serving cell, thus leading to ping-pong handovers. If this parameter is set to a higher value, the MS is unlikely to be handed over to the original serving cell. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |