Parameter Name |
Filter Parameter B |
---|---|
Description |
This parameter is used for configuring the filter for the rapidly dropped receive level. This parameter indicate specifies the drop trend of the receive level within a period. If this parameter is set to a higher value, a more rapid level drop is required for triggering a rapid level drop handover. This parameter is used together with the Filter Parameters A1 to A8. For details, refer to Filter Parameters A1-A8. |
GUI Value Range |
[0,200] |
Default Value |
0 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a higher value, a more rapid level drop is required for triggering a rapid level drop handover. |
Recommended Value |
0 |
Parameter Relationship |
Filter Parameter A1 to Filter Parameter A8 |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is available only when HO Control Switch is set to HO Algorithm I. This parameter is invalid when the HO Control Switch is set to HO Algorithm II. |