Parameter Name |
Load Req.on Candidate Cell(%) |
---|---|
Description |
If the cell load is smaller than the value of this parameter, the cell can receive the MSs handed over from other cells. Otherwise, the cell rejects the MSs handed over from other cells. |
GUI Value Range |
[0,100] |
Default Value |
85 |
Unit |
% |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The setting of this parameter affects the load handover targeted to the cell. If it is set to a lower value, the number of handover requests that are rejected increases. |
Recommended Value |
85 |
Parameter Relationship |
Load HO Allowed |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
The Load HO Threshold and Load Req.on Candidate Cell parameters affect the sorting of candidate cells. Therefore, when the cell load is high, if this parameter is improperly set, the PBGT handover may fail. |