Load HO Step Period

Parameter Name

Load HO Step Period

Description

When the load of the cell is equal to or greater than the Load HO Threshold, all the calls served by the cell may send handover requests simultaneously, and the load on the CPU will increase rapidly as a consequence. In some cases, call drops may occur due to traffic congestion in the cell. Therefore, the hierarchical handover algorithm for load handover is used for the BSC to control the number of users to be handed over by levels.

This parameter specifies the period for each load handover level.

GUI Value Range

[1,255]

Default Value

10

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

The setting of this parameter affects the load handover time. If it is set to a too greater value, the handover time of each level is long.

Recommended Value

10

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential