Layer HO Valid Time(s)

Parameter Name

Layer HO Valid Time(s)

Description

According to the P/N criterion, if the signals in the candidate cell are better than those in the serving cell for P consecutive times within N times, a layered hierarchical handover is triggered.

This parameter corresponds to P of the P/N criterion.

GUI Value Range

[1,16]

Default Value

2

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

The greater the value of this parameter is set, the more difficult the layered hierarchical handover can be triggered.

Recommended Value

2

Parameter Relationship

Layer HO Watch Time(s)

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

This parameter is available only when HO Control Switch is set to HO Algorithm I. This parameter is invalid when the HO Control Switch is set to HO Algorithm II.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.