Parameter Name |
PBGT Watch Time(s) |
---|---|
Description |
According to the P/N criterion, if the adjacent cell keeps meeting the triggering conditions of PBGT handover for P consecutive times within N times, a PBGT handover is triggered and the MS is handed over to the adjacent cell. This parameter corresponds to N of the P/N criterion. |
GUI Value Range |
[1,16] |
Default Value |
3 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is set, the more difficult the PBGT handover can be triggered. |
Recommended Value |
3 |
Parameter Relationship |
PBGT Valid Time(s) |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is available only when HO Control Switch is set to HO Algorithm I. This parameter is invalid when the HO Control Switch is set to HO Algorithm II. |