Parameter Name |
MS Fast-moving Watch Cells |
---|---|
Description |
According to the P/N criterion, if the MS fast passes P cells among the N micro cells, the BSC starts to trigger a fast-moving micro-to-macro cell handover. This parameter corresponds to N of the P/N criterion. |
GUI Value Range |
[1,10] |
Default Value |
3 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The more the micro cells are configured, the more difficult the fast-moving micro-to-macro cell handover can be triggered. If this parameter is set to a too great value, the system traffic volume cannot be reduced effectively; if this parameter is set to a too small value, the judgment on whether the MS fast passes a cell may be incorrect. |
Recommended Value |
3 |
Parameter Relationship |
MS Fast-moving Valid Cells |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |