Parameter Name |
MAX Consecutive HO Times |
---|---|
Description |
This parameter determines the maximum number of consecutive intra-cell handovers allowed. If the interval of two continuous intra-cell handovers is shorter than a specified threshold, the two handovers are regarded as consecutive handovers. If multiple consecutive intra-cell handovers occur, the intra-cell handover is forbidden for a period. |
GUI Value Range |
[1,20] |
Default Value |
3 |
Unit |
Times |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a too small value, the intra-cell handover may not be timely; if this parameter is set to a too great value, the system resources may be wasted when intra-cell handovers occur frequently. |
Recommended Value |
3 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |