Parameter Name |
Forbidden time after MAX Times |
---|---|
Description |
When the number of consecutive intra-cell handovers reaches the maximum allowed, a timer is started to forbid the intra-cell handover. Intra-cell handovers are allowed only when the timer expires. |
GUI Value Range |
[1,200] |
Default Value |
20 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter to used to disable the intra-cell handover for a certain period. |
Recommended Value |
20 |
Parameter Relationship |
Interval for Consecutive HO Jud. |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |