Forbidden time after MAX Times

Parameter Name

Forbidden time after MAX Times

Description

When the number of consecutive intra-cell handovers reaches the maximum allowed, a timer is started to forbid the intra-cell handover.

Intra-cell handovers are allowed only when the timer expires.

GUI Value Range

[1,200]

Default Value

20

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

This parameter to used to disable the intra-cell handover for a certain period.

Recommended Value

20

Parameter Relationship

Interval for Consecutive HO Jud.

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential