Parameter Name |
RX_QUAL Threshold |
---|---|
Description |
One of the parameters that determine the coverage of the OL subcell and of the UL subcell. RX_QUAL Threshold = RQ (ranging from level 0 to level 7) x 10. If the Enhanced Concentric Allowed parameter is set to No, the coverage of the OL subcell and UL subcell is determined by RX_LEV Threshold, RX_LEV Hysteresis, RX_QUAL Threshold, TA Threshold, and TA Hysteresis. If the Enhanced Concentric Allowed parameter is set to Yes, the coverage of the OL subcell and UL subcell is determined by RX_QUAL Threshold, UtoO HO Received Level Threshold, OtoU HO Received Level Threshold, TA Threshold, and TA Hysteresis. |
GUI Value Range |
[0,70] |
Default Value |
60 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
60 |
Parameter Relationship |
Enhanced Concentric Allowed |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |