RX_QUAL Threshold

Parameter Name

RX_QUAL Threshold

Description

One of the parameters that determine the coverage of the OL subcell and of the UL subcell. RX_QUAL Threshold = RQ (ranging from level 0 to level 7) x 10.

If the Enhanced Concentric Allowed parameter is set to No, the coverage of the OL subcell and UL subcell is determined by RX_LEV Threshold, RX_LEV Hysteresis, RX_QUAL Threshold, TA Threshold, and TA Hysteresis. If the Enhanced Concentric Allowed parameter is set to Yes, the coverage of the OL subcell and UL subcell is determined by RX_QUAL Threshold, UtoO HO Received Level Threshold, OtoU HO Received Level Threshold, TA Threshold, and TA Hysteresis.

GUI Value Range

[0,70]

Default Value

60

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

60

Parameter Relationship

Enhanced Concentric Allowed

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential