Parameter Name |
TA Hysteresis |
---|---|
Description |
This parameter is one of the parameters that determine the coverage of the OL subcell and UL subcell. If the Enhanced Concentric Allowed parameter is set to No, the coverage of the OL subcell and UL subcell is determined by TA Hysteresis, RX_LEV Threshold, RX_LEV Hysteresis, RX_QUAL Threshold, and TA Threshold. If the Enhanced Concentric Allowed parameter is set to Yes, the coverage of the OL subcell and UL subcell is determined by TA Hysteresis, UtoO HO Received Level Threshold, OtoU HO Received Level Threshold, RX_QUAL Threshold, and TA Threshold. |
GUI Value Range |
[0,255] |
Default Value |
0 |
Unit |
Bit period (a bit period corresponds to 0.55 km) |
Step |
- |
Modification Rules |
None |
Configuration Policy |
Check whether the concentric cell is an enhanced concentric cell. The coverage of the OL subcell and of the UL subcell is determined by different factors. |
Recommended Value |
0 |
Parameter Relationship |
Enhanced Concentric Allowed |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |