Parameter Name |
UtoO Traffic HO Allowed |
---|---|
Description |
This parameter determines whether the traffic load in the UL subcell determines the UL subcell to OL subcell handover or the OL subcell to UL subcell handover in an enhanced concentric cell. When this parameter is set to Yes, If the call is in the OL subcell and if the OL to UL HO Allowed parameter is set to Yes, the OL subcell to UL subcell handover is triggered when the traffic load in the UL subcell is lower than En Iuo Out Cell Low Load Threshold. If the call is in the UL subcell and the UL subcell to OL subcell handover is triggered, and if the UL to OL HO Allowed parameter is set to Yes, a timer is started when the traffic load in the UL subcell is greater than En Iuo Out Cell General OverLoad Threshold, thus handing over the MSs in the UL subcell to the OL subcell. If the traffic load in the UL subcell is lower than En Iuo Out Cell General OverLoad Threshold, the related timer is stopped, and the MSs in the UL subcell are not handed over to the OL subcell. When this parameter is set to No, the traffic load in the UL subcell is not taken into account for triggering the UL subcell to OL subcell handover or the OL subcell to UL subcell handover in an enhanced concentric cell. |
GUI Value Range |
[No,Yes] |
Default Value |
Yes |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
Yes |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is valid only when the Enhanced Concentric Allowed parameter is set to Yes. |