Parameter Name |
Underlay HO Step Level |
---|---|
Description |
During the handover from the UL subcell to the OL subcell, the calls are hierarchically handled from level 63 to 0. Therefore, the calls with higher receive level can be handed over to the OL subcell first. The handover strip is decreased by Underlay HO Step Level every Underlay HO Step Period. This parameter, together with Underlay HO Step Period, controls the level strip of the handover from the UL subcell to the OL subcell. In other words, the time taken in subtracting Underlay HO Step Level from the handover strip is Underlay HO Step Period. |
GUI Value Range |
[1,63] |
Default Value |
5 |
Unit |
Levels |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter is valid only when the Enhanced Concentric Allowed parameter is set to Yes. |
Recommended Value |
5 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |