Parameter Name |
Filter Length for SDCCH CV_BEP |
---|---|
Description |
This parameter specifies the number of Enhanced Measurement Reports used for averaging the CV_BEP on the SDCCH. By setting this parameter, you can use the CV_BEP in multiple EMRs, thus avoiding the case that the CV_BEP in a single EMR is inaccurate. This parameter should be set to a small value because the SDCCH seizure duration is shorter than the TCH seizure duration for the MS. |
GUI Value Range |
[0,31] |
Default Value |
2 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter should be set to a small value because the SDCCH seizure duration is shorter than the TCH seizure duration for the MS. |
Recommended Value |
2 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |