Filter Length for SDCCH REP_QUANT

Parameter Name

Filter Length for SDCCH REP_QUANT

Description

When the Measurement Report Type is EMR, this parameter specifies the length of the filter for the SDCCH REP_QUANT.

By setting this parameter, you can use the REP_QUANT in multiple EMRs, thus avoiding the case that the REP_QUANT in a single EMR is inaccurate.

GUI Value Range

[0,31]

Default Value

2

Unit

None

Step

-

Modification Rules

None

Configuration Policy

This parameter should be set to a small value because the SDCCH seizure duration is shorter than the TCH seizure duration for the MS.

Recommended Value

2

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.