Parameter Name |
Inter-layer HO Hysteresis |
---|---|
Description |
This parameter specifies the hysteresis of an inter-layer or inter-priority handover. This parameter is used to avoid inter-layer ping-pong handovers. Actual Inter-layer HO Threshold of a serving cell = configured Inter-layer HO Threshold - Inter-layer HO Hysteresis Actual Inter-layer HO Threshold of an adjacent cell = configured Inter-layer HO Threshold + Inter-layer HO Hysteresis of an adjacent cell - 64. |
GUI Value Range |
[0,63] |
Default Value |
2 |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
2 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |